* SYSINCLUDE had user-defined rows that were referenced in programs and dictionaries.
* HELP was used as a repository of setup data. * OBJECT had user-defined dictionary equates that were referenced in programs and dictionaries. * VOC dictionary had custom items * VOC had many custom items * Menus: All had the value of the Application in field 2 of the menu record. Had to be removed in order to run it.
1
out of
1 found this valuable.
Do you?
Keyword tags:
Advanced Revelation
AREV32
|
|||||
| dharmacek | Programs that must be copied to OI before the conversion | 0 | Jun 23 2008, 9:19 AM EDT by dharmacek | ||
|
Thread started: Jun 23 2008, 9:19 AM EDT
Watch
You must copy any custom MFS and User-Defined Conversion programs to OpenInsight and successfully compile them in OI.
You will not need the ArevDOS version of those programs. (I mean that Arev32 will find the OI object code. True for any program.) (Note that User-Defined Conversion programs cannot contain a dot (.) in the name of the program. [MY_DATE] is OK, [MY.DATE] won't work.) (if anyone needs a do-nothing of PX_MFS please contact me)
1
out of
1 found this valuable.
Do you?
Keyword tags:
Advanced Revelation
AREV32
|
|||||
| dharmacek | When you Copy the data tables it will recompile the dictionaries | 0 | Jun 23 2008, 9:15 AM EDT by dharmacek | ||
|
Thread started: Jun 23 2008, 9:15 AM EDT
Watch
1) It places CTODICT.MFS on the new dictionary tables. This is not a MFS known to Arev of DOS and you can no longer use those tables in Arev of DOS. According to RevSoft this MFS provides the required underscored column names as required by OI.
2) During conversion wizard, when the Rebuild Dictionaries option fails on a Formula it places only "* Bypass Conversion error@ans = 'Arev32 Conversion Error - Can not compile'" in the Formula. The original formula that failed is nowhere to be found. I believe it should also contain the (commented out) original formula so we can repair this in Arev32. This is in the Bug Tracker as issue 1001. To be fixed in OI 9.0. (This was fixed for 8.0.7)
2
out of
2 found this valuable.